112 BUTTERFLY VALVE ROTALY DAMPER DIAPHRAGM CONTROLL VALVE BALL VALVE VALVE ULTRA SONIC VOLTEX FLOWMETER IMPERA FLOWMETER ULTRA SONIC FLOWMETER JIS, ANSI, DIN Nominal Size 700 (28) 800 (32) 900 (36) 1000 (40) 1100 (44) 1200 (48) L 206 (8.11) 240 (9.45) 240 (9.45) 300 (11.81) 300 (11.81) 350 (13.78) H 1075 (42.32) 1155 (45.47) 1240 (48.82) 1300 (51.18) 1429 (56.26) 1479 (58.23) W 852 (33.54) 952 (37.48) 952 (37.48) 989 (38.94) 1079 (42.48) 1079 (42.48) P 722 (28.43) 897 (35.31) 897 (35.31) 1007 (39.65) 1072 (42.20) 1072 (42.20) Unit:mm(inch) W P H L PDCPD Butterfly Valve (Electric Actuated Type S) 700mm - 1200mm(28inch - 48inch) ■ As the Specific Qravity of PDCPD is less than 1/4 that of Iron the Valve Weighs Significantly lighter than Metal Butterfly Valves. ■ Superior Watertightness using Seat Packing made of Synthetic Rubber. ■ Standard Torque Switch protects Valves from Overload. ■ Automatic Return does not require Clutch Operation after Manual Operation. ■ Stopper enables Adjustment of an angle of ±5 degree at fully- Opened or Fully-Closed position. FEATURES OPTIONAL EQUIPMENT Combination No. 1 2 3 4 Space Heater ● ● ● ● Output Contact Limit Swiches ○ − − − Potentiometer − ○ ○ ○ R-I Transmitter − − ○ ○ E-E Positioner − − − ○ Body Material PDCPD Seat & O-ring Material EPDM Connection Standard JIS 10K ANSI CLASS150 DIN PN10 Power Source Three-Phase AC200V/400V Equipment Manual Operation Mechanism (with handle) Torque Switches Space Heater Indicator Option Output Contact Limit Switches Potentiometer R/I Transmitter E-E Positioner ※ Actuator type is to be changed ●Standard Equipment ※Actuator Type is to be changed. Applications Irrigation water, city water and sewage, thermal accumulators in buildings, various pipings such as for sea water, chemicals and air, and so on. Stop Potentiometer Potentiometer (Optional) Off by full open On by full open Off by full shut On by full shut Off by over torque of open direction Off by over torque of shut direction fuse source R/I converter (Optional) Space heater(standard accessory) M F NFB RST THR R R F F R OLS SLS THR R1 T1 OTLS STLS R F NFB R1 T1 A1 A2 A B C A 4〜20 mA DC Open Shut Inside of Actuator Inside of Actuator STLS Shut torque OTLS Open torque Open"a"contact point OLS Shut limit SLS OLS Open limit Output signal Power Circuit Operation Circuit SLS Shut"a"contact point U V W Full Open Full Shut abnormality WIRING DIAGRAM 2 1 5 10 12 11 13 9 6 3 4 7 8 C B H1 H2 R1 T1 A1 A2 A Switching Chart shut open DIMENSIONS FIGURE SCHEMATIC DIAGRAM DIMENSIONS TABLE ACTUATOR SPECIFICATION Nominal Size mm 700(28inch) 800・900(32inch・36inch) 1000(40inch) 1100 - 1200(44inch - 48inch) Actuator Type LTMD-02/BRL-10 LTMD-05/BRL-10 LTMD-1/BRL-20 LTMD-1/BRL-20 Cycle Time 50/60Hz(seconds) 74/61 71/75 46/51 59/59 Motor Output(W) 750 750 2200 2200 Motor Starting Current(A) 50/60Hz 200V 15.6/15.2 15.6/15.2 49.0/45.0 49.0/45.0 400V 7.8/7.6 7.8/7.6 24.5/22.5 24.5/22.5 Motor Rated Current(A) 50/60Hz 200V 4.4/4.0 4.4/4.0 11.4/10.4 11.4/10.4 400V 2.2/2.0 2.2/2.0 5.7/5.2 5.7/5.2 Number of revolutions of manual operating handle 15 333 333 618 Limit Switch Capacity AC 250V 5A Protective Structure IP55 Cable Connector Nominal Size Operation Circuit: 2-G1 Motor Circuit: G3/4 Motor Pole(P) 4 Motor Insulation E Class Motor Time Rating(minute) 15min. ※In the case of actuator with electric positioner, the model number is followed by "Z". Example:LTMD-02Z/BRL-10 ※1100mm(44inch) DIN not Available. WORKING PRESSURE VS.TEMPERATURE {10.2} 1.0 0.5 0.0 {5.1} 60 80 100 120 [150] [70] -40 -20 0 20 40 (-40) (-5) (30) (90) (105) (140) (175) (210) (250) Temperature℃(゜F) {10.2} 1.0 0.5 0.0 {5.1} 60 80 100 120 [150] [70] -40 -20 0 20 40 (-40) (-5) (30) (90) (105) (140) (175) (210) (250) Temperature℃(゜F) PDCPD PDCPD PDCPD PDCPD Max Working Pressure MPa{kgf/cm2}[PSI] 700mm(28inch) - 1000mm(40inch) Max Working Pressure MPa{kgf/cm2}[PSI] 1100mm(44inch),1200mm(48inch)