【DO!BOOK・ページリンク】
valve_piping   119 / 222

BOOKをみる

10秒後にBOOKのページに移動します


117 BUTTERFLY VALVE ROTALY DAMPER DIAPHRAGM VALVE ULTRA SONIC CONTROLL VALVE BALL VALVE VOLTEX FLOWMETER IMPERA FLOWMETER ULTRA SONIC FLOWMETER JIS, ANSI, DIN Nominal Size 50 (2) 80 (3) 100 (4) 125 (5) 150 (6) 200 (8) 250 (10) Common L 44 (1.73) 54 (2.13) 59 (2.32) 64 (2.52) 75 (2.95) 85 (3.35) 96 (3.78) H 268 (10.55) 302 (11.89) 346 (13.62) 375 (14.76) 428 (16.85) 502 (19.76) 583 (22.95) Double acting W 82 (3.23) 95 (3.74) 116 (4.57) 116 (4.57) 142.5 (5.61) 150 (5.90) 181 (7.13) P 210 (8.27) 250 (9.84) 292 (11.50) 292 (11.50) 362 (14.25) 440 (17.32) 532 (20.94) Air to open, Air to close W 103 (4.06) 118.5 (4.67) 141.5 (5.57) 141.5 (5.57) 174 (6.86) 192.5 (7.58) 231 (9.10) P 345 (13.58) 413 (16.26) 487 (19.17) 487 (19.17) 598 (23.54) 762 (30.00) 924 (36.38) Unit:mm(inch) Butterfly Valve Type 55 (Pneumatic Actuated Type TA)50mm・80mm - 250mm(2・3inch - 10inch) ■ Horizontal Type Actuator saves Piping Space. ■ Spring unit for Air to Open & Shut is detachable so that Change-over between Double-Acting and Air to Open & Shut can be done easily. ■ Various Options can be easily installed or removed and can be mounted later(except Positioners). ■ Stopper enables Adjustment of angle of ±5 degree at fully-Opened or Fully-Closed position. FEATURES OPTIONAL EQUIPMENT ACTUATOR SPECIFICATION [Double Acting] Body Material FCD-S Seat & O-ring Material PTFE (Cushion:CR) Connection Standard JIS 10K ANSI CLASS150 DIN PN10 Action Double Acting Air to Open Air to Close Equipment ・Opening Adjustment Stopper ( ± 5 degree) ・Indicator Option ・Filter Regulator ・Solenoid Valve ※ with built-in specialized speed controller and bypass valve. ・Limit Switch ・Speed Controller ・Manual Operation Mechanism ※ Only for air to open & close. ・ Full Opening Adjustment Mechanism ・Positioner Combination No. 1 2 3 4 5 6 7 8 9 Solenoid Valve ※ ○ − − ○ ○ − ○ − − Filter Regulator − − − ○ − − ○ − ○ Speed Controller ◎ ○ − ◎ ◎ ○ ◎ − − Limit Switch − − ○ − ○ ○ ○ − − Positioner (Electric-Air, Air-Air) − − − − − − − ○ ○ ◎Indicates specialized for Solenoid Valve. ※With built-in speed controller and bypass valve. Nominal Size mm(inch) 50(2inch) 80(3inch) 100・125(4inch・5inch) 150(6inch) 200(8inch) 250(10inch) Actuator Type TA2A-050D TA2A-063D TA2A-080D TA2A-100D TA2A-125D TA2A-160D Operating Pressure MPa{kgf/cm2} 0.4{4.1} - 0.7{7.1} Air Consumption Nl /open & close (at operating pressure 0.4MPa) 0.9 1.7 3.2 6.6 13.3 27.1 Air Supply Bore Rc 1/4 Nominal Size mm(inch) 50(2inch) 80(3inch) 100・125(4inch・5inch) 150(6inch) 200(8inch) 250(10inch) Actuator Type TA2A-050R TA2A-063R TA2A-080R TA2A-100R TA2A-125R TA2A-160R Operating Pressure MPa{kgf/cm2} 0.4{4.1} - 0.7{7.1} Air Consumption Nl /open & close (at operating pressure 0.4MPa) 1.7 3.3 6.1 12.8 21.6 42.7 Air Supply Bore Rc 1/4 DIMENSIONS FIGURE DIMENSIONS TABLE Double Acting H W L P W H L P Double Acting Air to Open Air to Close ACTUATOR SPECIFICATION [Air to Open, Air to Close] Air to Open Air to Close WORKING PRESSURE VS.TEMPERATURE {10.2} 1.0 0.5 0.0 {5.1} 60 80 100 120 [150] [70] -40 -20 0 20 40 (-40) (-5) (30) (90) (105) (140) (175) (210) (250) Temperature℃(゜F) FCD-S FCD-S Max Working Pressure MPa{kgf/cm2}[PSI] 50mm(2inch) - 250mm(10inch)