yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz
valve_piping@@@121 / 222

BOOK‚ð‚Ý‚é

10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚·


119 BUTTERFLY VALVE ROTALY DAMPER DIAPHRAGM VALVE ULTRA SONIC CONTROLL VALVE BALL VALVE VOLTEX FLOWMETER IMPERA FLOWMETER ULTRA SONIC FLOWMETER Rotary Damper (Electric Actuated Type S) 40mm - 600mm(11/2inch - 24inch) ¡ Speedy, exact operation by Motor with Direct Current Brake. ¡ Standard Torque Switch protects Valves from overload. ¡ Stopper enables Adjustment of an angle of }5degree when fullyopened or fully-closed. FEATURES OPTIONAL EQUIPMENT ACTUATOR SPECIFICATION DIMENSIONS FIGURE Full Open Full Shut Stop Potentiometer thermal protector Space heater standard accessory Off by full open On by full open Off by full shut On by full shut Off by over torque of open direction Off by over torque of shut direction Optional fuse abnormality source On by over torque of open direction On by over torque of shut direction M F U V W NFB R S T 8 R 4 R F F R R1 T1 OTLS-1 STLS-1 31 10 32 27 28 29 R F OLS-1 SLS-1 OLS-2 SLS-2 THP 2 5 9 17 13 THP 1 NFB Open Shut Inside of Actuator Inside of Actuator Shut limit Shut a" contact point STLS-1 Shut torque OTLS-1 Open torque SLS " -2 Open a" contact point OLS -1 OLS -2 SLS -1 " Open limit Switching chart Shut Open power circuit operation circuit OTLS-2 STLS-2 18 14 STLS-2 OTLS-2 Open torque Shut torque 6 WIRING DIAGRAM SCHEMATIC DIAGRAM DIMENSIONS TABLE Body Material PVC PP PVDF Seat & O-ring Material EPDM FKM Connection Standard JIS 10KEJIS 5K ANSI CLASS150 DIN PN10 Power Source Three-Phase AC200V/220V/400V/440V Equipment Manual Operation Mechanism Torque Switches Output Contact Limit Switches Space Heater Indicator Option Potentiometer R/I Transmitter E-E Positioner Nominal Size mm(inch) 40-150(11/2inch-6inch) 200-350(8inch-14inch) 400(16inch) 450-600(18inch-24inch) Valve Type Type 57 Type 56 Type 75 Actuator Type SRJ-010 SRJ-020 SRJ-060 Cycle Time 50/60Hz(seconds) 18/15 36/30 36/30 Motor Output(W) 40 100 Motor Starting Current(A) 50/60Hz 200V 1.27/1.19 1.89/1.77 400V 0.63/0.58 0.94/0.90 Motor Rated Current(A) 50/60Hz 200V 0.53/0.45 0.74/0.67 400V 0.26/0.22 0.37/0.34 Number of revolutions of manual operating handle 21 26 Limit Switch Capacity AC 250V 2A Protective Structure IP68 Cable Connector Nominal Size 3-G1 Motor Pole(P) 4 Motor Insulation B Class Motor Time Rating(minute) 15 Combination No. 1 2 3 Space Heater œ œ œ Output Contact Limit Swiches œ œ œ Potentiometer › › › R-I Transmitter | › › E-E Positioner | | › JIS, ANSI, DIN Nominal Size 40 (1 1/2) 50 (2) 65 (2 1/2) 80(75) (3) 100 (4) 125 (5) 150 (6) 200 (8) 250 (10) 300 (12) 350 (14) 400 (16) 450 (18) 500 (20) 600 (24) L 32 35 37 37 47 57 62 76 96 116 116 157 167 177 197 (1.26) (1.38) (1.46) (1.46) (1.85) (2.24) (2.44) (2.99) (3.78) (4.57) (4.57) (6.18) (6.58) (6.97) (7.76) H U-PVC, PP 313 323 333 348 363 398 413 444 486 543 570 612 623 653 717 (12.32) (12.72) (13.11) (13.70) (14.29) (15.67) (16.26) (17.48) (19.14) (21.38) (22.44) (24.10) (24.53) (25.71) (28.23) PVDF 333 343 353 368 383 418 433 464 506 563 590 632 648 678 742 (13.11) (13.51) (13.90) (14.49) (15.08) (16.46) (17.05) (18.27) (19.92) (22.17) (23.23) (24.89) (25.52) (26.70) (29.22) W 390 390 390 390 390 390 390 390 390 390 390 460 460 460 460 (15.36) (15.36) (15.36) (15.36) (15.36) (15.36) (15.36) (15.36) (15.36) (15.36) (15.36) (18.11) (18.11) (18.11) (18.11) P 353 353 353 353 353 353 353 353 353 353 353 393 393 393 393 (13.90) (13.90) (13.90) (13.90) (13.90) (13.90) (13.90) (13.90) (13.90) (13.90) (13.90) (15.47) (15.47) (15.47) (15.47) Unit:mm(inch) œStandard Equipment P W H L WORKING PRESSURE VS.TEMPERATURE o10.2p 1.0 0.5 0.0 o5.1p o10.2p 1.0 0.5 0.0 o5.1p 60 80 100 120 [150] [70] -40 -20 0 20 40 i30j i140j i175j i210j i250j -5 i20j -5 i20j i-40j i-5j i90j i105j TemperatureŽiKFj 60 80 100 120 [150] [70] -40 -20 0 20 40 i-40j i-5j i30j i90j i105j i140j i175j i210j i250j TemperatureŽiKFj PVC PVC PVC PVC PVDF PVDF PVDF PVDF PP PP PP PP 40mm(11/2inch) - 200mm(8inch) 250mm(10inch)-600mm(24inch) Max Working Pressure MPa{kgf/cm2}[PSI] Max Working Pressure MPa{kgf/cm2}[PSI]