【DO!BOOK・ページリンク】
av-en-pipe   174 / 199

BOOKをみる

10秒後にBOOKのページに移動します


172 Size (mm) Product Display Insertion length (minimum) (mm) Heat Fusion Time (sec) Conversion Time (sec) Cooling Time (sec) Retaining Total 15 d20 14.5 5 4 6 120 (2min) 20 d25 16.0 7 4 10 120 (2min) 25 d32 18.0 8 6 10 240 (4min) 32 d40 20.5 12 6 20 240 (4min) 40 d50 23.5 12 6 20 240 (4min) 50 d63 27.5 24 8 30 360 (6min) Size (mm) Product Display Insertion length (minimum) (mm) Heat Fusion Time (sec) Conversion Time (sec) Cooling Time (sec) Retaining Total 20 d25 16.0 7 4 10 120 (2min) 25 d32 18.0 8 6 10 240 (4min) 32 d40 20.5 12 6 20 240 (4min) 40 d50 23.5 12 6 20 240 (4min) 50 d63 27.5 24 8 30 360 (6min) 65 d75 31.0 30 8 30 360 (6min) 80 d90 35.5 40 8 40 360 (6min) 100 d110 41.5 50 10 50 480 (8min) * Heater temperature: 260±10℃ * 100 mm: Only reducer (125x100 mm) is fusible. ■ Socket Fusion R63 ■ Socket Fusion PRISMA125 ■ Socket Fusion AV225 * Heat Fusion Time: Time from completion of insertion * Conversion Time: Time from completion of heating to completion of crimping * Retaining Time: Time while fixed on fusion machine clamp (For R63, time while fixed manually) * Cooling Time: Time to cool without clamp Fusion Conditions Size (mm) Product Display Heat Fusion Time (sec) Conversion Time (sec) Retaining Time (sec) Cooling Time (min) PN10/SDR11 PN4/SDR26 100 d110 60 . 20 60 8 125 d140 90 45 20 90 8 150 d180 120 60 20 120 10 200 d225 150 75 20 150 10 Installation Procedure