126 . EQUIPPED WITH FAILSAFE LIMIT SWITCH IN ADDITION TO STANDARD ON/OFF LIMIT SWITCH. OUTPUT CONTACT LIMIT SWITCH IS ALSO PROVIDED AS STANDARD. . LARGE OPENING DISPLAY PROVIDES CLEAR INDICATION. . EQUIPPED WITH MANUAL OVERRIDE FUNCTION THAT ALLOWS FOR MANUAL OPERATION BEFORE ENERGIZATION AND DURING POWER OUTAGE. ELECTRIC TYPE H OPTION LIST MANUFACTURER BASIC SPECIFICATIONS SPACE HEATER SHINWA CONTROLS . STANDARD EQUIPMENT OUTPUT CONTACT LIMIT SWITCH AZBIL . INCLUDED AS STANDARD. POTENTIOMETER SHINWA CONTROLS . RESISTANCE: 500Ω, 1000Ω, 2000Ω, 5000Ω, 10000Ω Note) When a potentiometer is provided, the  output contact limit switch is not provided. MANUAL OVERRIDE SHINWA CONTROLS . INCLUDED AS STANDARD. SPECIAL PAINTING (ACTUATOR ONLY) ASAHI YUKIZAI . EPOXY PAINT, POLYURETHANE PAINT ● indicates that the feature is provided as standard. * For the specifications of positioner and potentiometer (optional), contact us. When a potentiometer is provided, the output contact limit switch is not provided. OPTION COMBINATION COMBINATION NO. 1 SPACE HEATER ● OUTPUT CONTACT LIMIT SWITCH ● DIAPHRAGM VALVE APPLICABLE TYPE ACTUATOR TYPE UNIT ED-11H ED-21H ED-30H VAVLVE SIZE (mm) 15 20 25 32 40 50 65 80 100 125 150 CYCLE TIME 50Hz 20 24 43 51 38 47 56 48 s 60Hz 16 20 36 43 32 39 47 40 PROTECTIVE STRUCTURE JIS C0920 WATER PROOF BASIC SPECIFICATIONS MOTOR STARTING CURRENT 50/60Hz AC100V 0.69/0.7 2.3/2.2 5.0/4.8 A AC200V 0.3/0.3 1.15/1.1 2.5/2.4 MOTOR RATED CURRENT 50/60Hz AC100V 0.5/0.5 1.5/1.8 3.0/3.0 A AC200V 0.25/0.25 0.8/0.8 1.5/1.5 NUMBER OF REVOLUTIONS OF MANUAL OPERATING HANDLE 21 25 44 52 76 94 112 128 POWER CONSUMPTION AC100V 47.5 142.5 285 W AC200V 47.5 143 285 CABLE CONNECTOR SIZE 2-G3/4 4-G3/4 MOTOR RATED OUTPUT 20 60 140 W MOTOR INSULATION TYPE E CLASS MOTOR RATED TIME 30 min LIMIT SWITCH CAPACITY AC250V 10A SPACE HEATER OUTPUT 10W(100V: 1kΩ, 200V: 4kΩ) 1kΩ 10W POTENTIOMETER MAX. APPLIED VOLTAGE 8 8 V Thermal protector Actuator SW3 SW1 SW4 SW2 * Two motors are provided only for ED-30H. Red Blue White Brown Open Selector switch Close Yellow Black Open Close Error Space heater (standard feature) Yellow/white Green/white SW5 (Open) Gray Green Pink EMPTY Output contact limit switch (standard feature) Open Purple Close SW6 (Close) Orange Potentiometer (optional) Red/white Blue/white Black/white OFF at full close overrun. OFF at full open overrun. OFF at full close. OFF at full open. P1-P3 is ON at slightly before full open. P4-P6 is ON at slightly Closed No-voltage before full closed. SW4 SW6 Closed Failsafe SW5 SW2 Closed Limit Open No-voltage SW3 Open Failsafe Open Limit SW1 Open Closed Note) When a potentiometer is provided, no output contact limit switch is provided. Thermal protector * Two motors only for ED-30H. Space (standard Output limit (standard Potentiometer (optional) OFF at full close overrun. OFF at full open overrun. OFF at full close. OFF at full open. P1-P3 is ON at slightly before full open. P4-P6 is ON at slightly Closed No-voltage before full closed. SW4 SW6 Closed Failsafe SW5 SW2 Closed Limit Open No-voltage SW3 Open Failsafe Open Limit SW1 Open Closed Note) When a potentiometer provided, no limit switch is OPTION COMBINATION